| Ablation study #1 (Assess loss function) | Ablation study #2 (Assess input channels | |||||
| Constant | T2-prepared images | Huber Loss | ||||
| Variable | MSE | MAE | Huber (δ=0.05) | T2-prepared images | T2 map | T2-prepared images + T2 map |
| RV & LV Test | 0.89 | 0.92 | 0.95 | 0.95 | 0.92 | 0.94 |
| RV Test | 0.22 | 0.34 | 0.60 | 0.60 | 0.44 | 0.55 |
| LV Test | -3.47 | -0.21 | 0.21 | 0.21 | -1.50 | -0.45 |
| 5% Accuracy | 0.86 | 0.84 | 0.91 | 0.91 | 0.82 | 0.86 |
Figure 2: Performance evaluation of DeepOx O2Sat predictions compared to reference O₂ saturation measurements. (a) Scatter plot of chamber-averaged DeepOx predictions versus reference O₂ saturation (catheter for right ventricle and pulse oximeter for left ventricle) for training (blue) and testing (red) datasets.(b) Comparison of RV O2 saturation results between DeepOx (red) and model-based oximetry (green) with respect to reference catheter-based measurements. Bland–Altman plots for (c) DeepOx and (d) model-based oximetry. .jpg)