Figure 2: Volumetric analysis comparison between the 2ch, 3ch, and 4ch + 3SAX methods while using full-stack values from SAX slices as reference for 507 patients. Here, CCC = Concordance Correlation Coefficient, Limits of Agreement in the Bland-Altman Analysis are +- 1.96 * Standard Deviation (SD). Bold text indicates the best results. EDV = End Diastolic Volume; ESV = End Systolic Volume; SV = Stroke Volume; EF = Ejection Fraction, CI = Confidence Intervals
Figure 3: Bland-Altman analysis for 2ch + 3SAX method with full-stack as reference. The dashed green line represents bias whereas the dotted red and the yellow lines represent the 95% Limits of Agreement. .png)