Rapid Fire Session
Ilkay Oksuz, PhD
Associate Prof.
Computer Engineering Department, Istanbul Technical University, Istanbul, Turkey
İstanbul , Istanbul, Turkey
Ruru Xu
PhD Candidate
Computer Engineering Department, Istanbul Technical University, Istanbul, Turkey, Turkey
| Center | Scanner Config | HyperCMR | HierAdaptMR | Improvement | ||
| SSIM | PSNR | SSIM | PSNR | SSIM/PSNR | ||
| C001 | UIH-3.0T | 0.695 | 28.30 | 0.873 | 31.79 | +25.6%/+12.3% |
| C002 | Siemens-3.0T | 0.682 | 25.01 | 0.797 | 28.34 | +16.9%/+13.3% |
| UIH-3.0T | 0.770 | 27.44 | 0.856 | 31.20 | +11.2%/+13.7% | |
| C003 | UIH-3.0T | 0.808 | 29.31 | 0.878 | 32.86 | +8.7%/+12.1% |
| C004 | Siemens-1.5T | 0.726 | 26.38 | 0.829 | 29.97 | +14.2%/+13.6% |
| C005 | GE-1.5T | 0.846 | 30.30 | 0.904 | 33.78 | +6.9%/+11.5% |
| Siemens-3.0T | 0.745 | 27.14 | 0.874 | 31.18 | +17.3%/+14.9% | |
| C006 | Siemens-3.0T | 0.753 | 27.40 | 0.866 | 31.14 | +15.0%/+13.6% |
| UIH-3.0T | 0.845 | 29.62 | 0.916 | 33.65 | +8.4%/+13.6% | |
| C008 | GE-1.5T | 0.823 | 28.83 | 0.886 | 32.12 | +7.7%/+11.4% |
| Overall Mean | 0.769 | 27.97 | 0.868 | 31.60 | +12.9%/+13.0% | |
Qualitative cross-center reconstruction results on CMRxRecon2025 validation set. Each column represents a different center configuration with varying undersampling patterns. From top to bottom: masked k-space with undersampling artifacts, recovered k-space, and final reconstructed cardiac images.